Shipboard Control Cables | IEC 60092-376 | CCS/BV/ABS/DNV Certified
As a specialist marine cable supplier, we offer high-performance marine control cables that meet IEC 60092-376 and major class society approvals (CCS, BV, ABS, DNV, etc).
Our cables feature flame-retardant LSZH sheathing, oil/fuel resistance, and effective electromagnetic shielding – ensuring reliable control signal transmission for ship automation, alarm, monitoring, and propulsion systems. Designed to withstand salt spray, humidity, vibration, and extreme temperatures.
Available in multi-core and shielded configurations for new builds or retrofits. Each cable is strictly tested for safety and durability.
Available in multi-core, twisted pair, and shielded configurations for new builds or retrofits. Each cable is strictly tested for safety and durability.
Slide to bottom of this page for PDF datasheet then contact us to get a quote
Overview
1 What Are Shipboard Control Cables
Also called marine control cable, designed for fixed installation in control, instrumentation, alarm & monitoring circuits on ships and offshore units.
Rated voltage: 150/250V (300V) per IEC 60092-376.
Focus on signal integrity, EMC immunity, flame safety and marine durability.
2 Chinese Marine Control Cable Code Explanation
Want to know more about marine cable code? Please check the following link:
3 Overview of Technical Parameters
Rated Voltage: 150/250V (300V)
Conductor: Tinned copper, Class 2 / Class 5 flexible
Cores: 2–37 cores
Cross-section: 0.5–2.5 mm²(For larger conductor size or power applications, refer to our shipboard power cable)
Insulation: XLPE / EPR / PVC
Screen: Collective / Individual + Collective
Armor: Galvanized steel / Tinned copper braid
Sheath: LSZH (SHF1/SHF2) / PVC
Flame: IEC
60332-1-2 / 60332-3-22 A
Fire Resistant: IEC 60331 (950℃, 180min)
LSZH: IEC 61034 / IEC 60754-2
4 Analysis of Technical Specification
4.1 Rated Voltage
Shipboard control cables are rated at 150/250V (300V) per IEC 60092-376. This lower voltage rating reflects their intended role in control circuits — pilot lamp circuits, alarm circuits, monitoring systems, and general control loops — not main power distribution. For power transmission applications (0.6/1kV and above), please refer to our shipboard power cable product page.
4.2 Insulation Material
PVC: Suitable for general-purpose control circuits where LSZH is not mandatory. Not recommended for enclosed space due to smoke emission in fire.
EPR (Ethylene Propylene Rubber): With excellent flexibility and superior bending resistance, it is particularly suitable for deck machinery and control circuits with frequent vibrations. Its good electrical stability ensures reliable signal transmission.
XLPE (Cross-linked Polyethylene): Delivers high continuous operating temperature (90℃), with stable electrical performance, high insulation resistance, and low dielectric loss, it is suitable for control circuits that require signal integrity. Additionally, it offers cost-effective advantages.
4.3 Screening (When Required)
For applications with electromagnetic interference concerns (e.g. installations near propulsion motors, generators, or radio transmitters), a collective braided screen (tinned copper wire) is applied over all cores assembly. Collective braided screen provides effective electrostatic shielding against external interference.
4.4 Flame Retardant & Fire Resistant
Flame Retardant Shipboard Control Cable: Complies with IEC 60332-3-22 Category A, preventing the spread of fire along bundled cable runs — essential for maintaining system segregation in fire scenarios.
Fire Resistant Shipboard Control Cable: Compliant with IEC 60331, essential for emergency control circuits (emergency generator control, fire pump control, escape lighting control). The conductor is wrapped with fire-resistant mica tape, enabling the cable to maintain circuit integrity when exposed to 950℃ flame for up to 180 minutes.
4.5 Low-smoke Zero-halogen(LSZH)
LSZH shipboard control cables are mandatory for passenger ships, cruise vessels, and enclosed cabins. In a fire, these cables emit minimal smoke (≥60% light transmittance per IEC 61034) and no halogenated toxic gases (pH ≥4.3, conductivity ≤10 μS/mm per IEC 60754-2) — protecting personnel during evacuation and preventing corrosion of sensitive electronic equipment in control rooms.
4.6 Flexible conductor
Class 5 or Class 6 copper conductor: Provides superior flexibility with smaller bending radius than Class 2 conductor. Recommended for control cable runs with multiple bends, confined switchboard termination.
4.7 Armor type
Galvanized steel wire braided (Code 9): Provides high mechanical protection against tension and compression. Essential for vertical risers (multi-deck runs), exposed deck installations prone to impact damage.
Tinned copper wire braided (Code 8): Combines electromagnetic screening effectiveness with mechanical protection. Ideal for control circuits near high-power equipment where both physical protection and interference rejection are required. Also provides excellent corrosion resistance in marine environments.
5 Standard & Compliance
5.1 Core Standards for Shipboard Control Cables
Standard | Standard name | Scope of application |
IEC 60092-376 | Electrical installations in ships — Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) | Primary standard for control cables — defines construction, screening requirements, and test methods |
IEC 60092-350 | Electrical installations in ships — Part 350: Shipboard power cables — General construction and test requirements | Basic structural and test requirements applicable to all shipboard cables |
IEC 60092-360 | Electrical installations in ships — Part 360: Insulating and sheathing materials | Specifies materials for insulation and sheathing |
IEC 60228 | Conductors of insulated cables | Specified conductor construction (tinned copper, Class 2 & Class 5) |
5.2 Performance Standard
Performance | Standard | Requirement |
Single cable flame retardant | IEC 60332-1-2 | Passed |
Bunched cable flame retardant | IEC 60332-3-22 | Category A |
Fire resistant | IEC 60331 | 950℃, 180 min |
Low smoke | IEC 61034 | Light transmittance ≥60% |
Halogen free | IEC 60754-2 | pH ≥4.3, conductivity ≤10 μS/mm |
Oil resistance | IEC 60811-2-1 | Mineral oil, 100℃, 72h |
6 Application & Selection Guide
6.1 Recommended cable types by application
Application | Recommended control cable type | Key features |
Engine room — control systems | CKEPF86/SC or CKEPJ85/SC with EPR insulation | EPR flexibility, tinned copper wire braided screen; 90℃ rating for high ambient temperature |
Engine room — automation & monitoring | CKJPF/SC or CKJPJ/SC | XLPE insulation, LSZH |
Open deck / cargo hold | CKEPJ95/SC or CKEPF96/SC | Galvanized steel wire braided armor (high tensile strength), LSZH, flame retardant |
Enclosed cabin / passenger spaces | CKJPJ/SC or CKEPJ/SC | LSZH construction (SC rating), low smoke, zero halogen |
Bridge control console | CKEPF/SC (flexible conductor, SC = LSZH) | Class 5 flexible conductor, reduced bending radius, compact construction |
Emergency generator room — control | CKJPJ/NC (fire resistant) | IEC 60331 fire resistant, maintains circuit integrity in fire, LSZH |
6.2 Installation guidelines
Parameter | Value |
Maximum continuous operating conductor temperature | 90℃ |
Short-circuit temperature (≤5s) | ≤250℃ |
Minimum ambient temperature for installation | -20℃(or -5℃ per specific designs) |
Minimum bending radius — armored cable | ≥6 × D(cable outer diameter) |
Minimum bending radius — unarmored cable (D≤25mm) | ≥4 × D(cable outer diameter) |
Minimum bending radius — unarmored cable (D>25mm) | ≥6 × D(cable outer diameter) |
7 Available Type Approval Certificate
Our shipboard control cables are certified by leading classification societies:
CCS, BV, ABS, DNV, NK, RINA, etc.
8 Get A Quote — please provide the following information
Model/Construction
Number of cores and cross-section
Length
Type approval certificate required
Delivery port
8.1 Our Strengths
Ready stock for standard models
Low MOQ, cut-length available
Full set of documents & type approval
One-stop marine cable solution
8.2 Why Choose Us
Professional marine cable trader with years of experience
Full certification, no customs clearance issues
Stable quality & competitive price
Quick response & technical support
8.3 Download
Click following link for our Datasheet PDF