Shipboard Control Cables | IEC 60092-376 | CCS/BV/ABS/DNV Certified

Shipboard Control Cables | IEC 60092-376 | CCS/BV/ABS/DNV Certified


As a specialist marine cable supplier, we offer high-performance marine control cables that meet IEC 60092-376 and major class society approvals (CCS, BV, ABS, DNV, etc).

Our cables feature flame-retardant LSZH sheathing, oil/fuel resistance, and effective electromagnetic shielding – ensuring reliable control signal transmission for ship automation, alarm, monitoring, and propulsion systems. Designed to withstand salt spray, humidity, vibration, and extreme temperatures.

Available in multi-core and shielded configurations for new builds or retrofits. Each cable is strictly tested for safety and durability.

Available in multi-core, twisted pair, and shielded configurations for new builds or retrofits. Each cable is strictly tested for safety and durability.

Slide to bottom of this page for PDF datasheet then contact us to get a quote


Overview

1 What Are Shipboard Control Cables

Also called marine control cable, designed for fixed installation in control, instrumentation, alarm & monitoring circuits on ships and offshore units.

Rated voltage: 150/250V (300V) per IEC 60092-376.

Focus on signal integrity, EMC immunity, flame safety and marine durability.


2 Chinese Marine Control Cable Code Explanation

Want to know more about marine cable code? Please check the following link:

Marine Cable Code Explanation

 

3 Overview of Technical Parameters

Rated Voltage: 150/250V (300V)

Conductor: Tinned copper, Class 2 / Class 5 flexible

Cores: 2–37 cores

Cross-section: 0.5–2.5 mm²(For larger conductor size or power applications, refer to our shipboard power cable)

Insulation: XLPE / EPR / PVC

Screen: Collective / Individual + Collective

Armor: Galvanized steel / Tinned copper braid

Sheath: LSZH (SHF1/SHF2) / PVC

Flame: IEC

60332-1-2 / 60332-3-22 A

Fire Resistant: IEC 60331 (950℃, 180min)

LSZH: IEC 61034 / IEC 60754-2

 

4 Analysis of Technical Specification

4.1 Rated Voltage

Shipboard control cables are rated at 150/250V (300V) per IEC 60092-376. This lower voltage rating reflects their intended role in control circuits pilot lamp circuits, alarm circuits, monitoring systems, and general control loops not main power distribution. For power transmission applications (0.6/1kV and above), please refer to our shipboard power cable product page.

 

4.2 Insulation Material

PVC: Suitable for general-purpose control circuits where LSZH is not mandatory. Not recommended for enclosed space due to smoke emission in fire.

 

EPR (Ethylene Propylene Rubber): With excellent flexibility and superior bending resistance, it is particularly suitable for deck machinery and control circuits with frequent vibrations. Its good electrical stability ensures reliable signal transmission.

 

XLPE (Cross-linked Polyethylene): Delivers high continuous operating temperature (90), with stable electrical performance, high insulation resistance, and low dielectric loss, it is suitable for control circuits that require signal integrity. Additionally, it offers cost-effective advantages.

 

4.3 Screening (When Required)

For applications with electromagnetic interference concerns (e.g. installations near propulsion motors, generators, or radio transmitters), a collective braided screen  (tinned copper wire) is applied over all cores assembly. Collective braided screen provides effective electrostatic shielding against external interference.

 

4.4 Flame Retardant & Fire Resistant

Flame Retardant Shipboard Control Cable: Complies with IEC 60332-3-22 Category A, preventing the spread of fire along bundled cable runs essential for maintaining system segregation in fire scenarios.

 

Fire Resistant Shipboard Control Cable: Compliant with IEC 60331, essential for emergency control circuits (emergency generator control, fire pump control, escape lighting control). The conductor is wrapped with fire-resistant mica tape, enabling the cable to maintain circuit integrity when exposed to 950flame for up to 180 minutes.

 

4.5 Low-smoke Zero-halogen(LSZH)

LSZH shipboard control cables are mandatory for passenger ships, cruise vesselsand enclosed cabins. In a fire, these cables emit minimal smoke (60% light transmittance per IEC 61034) and no halogenated toxic gases (pH 4.3, conductivity 10 μS/mm per IEC 60754-2) protecting personnel during evacuation and preventing corrosion of sensitive electronic equipment in control rooms.

 

4.6 Flexible conductor

Class 5 or Class 6 copper conductor: Provides superior flexibility with smaller bending radius than Class 2 conductor. Recommended for control cable runs with multiple bends, confined switchboard termination.

 

4.7 Armor type

Galvanized steel wire braided (Code 9): Provides high mechanical protection against tension and compression. Essential for vertical risers (multi-deck runs), exposed deck installations prone to impact damage.

 

Tinned copper wire braided (Code 8): Combines electromagnetic screening effectiveness with mechanical protection. Ideal for control circuits near high-power equipment where both physical protection and interference rejection are required. Also provides excellent corrosion resistance in marine environments.


5 Standard & Compliance

5.1 Core Standards for Shipboard Control Cables

Standard

Standard name

Scope of application

IEC 60092-376

Electrical installations in ships — Part 376: Cables for control and instrumentation circuits 150/250 V (300 V)

Primary standard for control cables — defines construction, screening requirements, and test methods

IEC 60092-350

Electrical installations in ships — Part 350: Shipboard power cables — General construction and test requirements

Basic structural and test requirements applicable to all shipboard cables

IEC 60092-360

Electrical installations in ships — Part 360: Insulating and sheathing materials

Specifies materials for insulation and sheathing

IEC 60228

Conductors of insulated cables

Specified conductor construction (tinned copper, Class 2 & Class 5)


5.2 Performance Standard

Performance

Standard

Requirement

Single cable flame retardant

IEC 60332-1-2

Passed

Bunched cable flame retardant

IEC 60332-3-22

Category A

Fire resistant

IEC 60331

950℃, 180 min

Low smoke

IEC 61034

Light transmittance ≥60%

Halogen free

IEC 60754-2

pH ≥4.3, conductivity ≤10 μS/mm

Oil resistance

IEC 60811-2-1

Mineral oil, 100℃, 72h


6 Application & Selection Guide

6.1 Recommended cable types by application

Application

Recommended control cable type

Key features

Engine room — control systems

CKEPF86/SC or CKEPJ85/SC with EPR insulation

EPR flexibility, tinned copper wire braided screen; 90℃ rating for high ambient temperature

Engine room — automation & monitoring

CKJPF/SC or CKJPJ/SC

XLPE insulation, LSZH

Open deck / cargo hold

CKEPJ95/SC or CKEPF96/SC

Galvanized steel wire braided armor (high tensile strength), LSZH, flame retardant

Enclosed cabin / passenger spaces

CKJPJ/SC or CKEPJ/SC

LSZH construction (SC rating), low smoke, zero halogen

Bridge control console

CKEPF/SC (flexible conductor, SC = LSZH)

Class 5 flexible conductor, reduced bending radius, compact construction

Emergency generator room — control

CKJPJ/NC (fire resistant)

IEC 60331 fire resistant, maintains circuit integrity in fire, LSZH


6.2 Installation guidelines

Parameter

Value

Maximum continuous operating conductor temperature

90℃

Short-circuit temperature (≤5s)

≤250℃

Minimum ambient temperature for installation

-20℃(or -5℃ per specific designs)

Minimum bending radius — armored cable

≥6 × D(cable outer diameter)

Minimum bending radius — unarmored cable (D≤25mm)

≥4 × D(cable outer diameter)

Minimum bending radius — unarmored cable (D>25mm)

≥6 × D(cable outer diameter)


7 Available Type Approval Certificate

Our shipboard control cables are certified by leading classification societies:

CCS, BV, ABS, DNV, NK, RINA, etc.

 

8 Get A Quote please provide the following information

Model/Construction

Number of cores and cross-section

Length

Type approval certificate required

Delivery port

 

8.1 Our Strengths

Ready stock for standard models

Low MOQ, cut-length available

Full set of documents & type approval

One-stop marine cable solution

 

8.2 Why Choose Us

Professional marine cable trader with years of experience

Full certification, no customs clearance issues

Stable quality & competitive price

Quick response & technical support

 

8.3 Download

Click following link for our Datasheet PDF