6kV to 30kV Copper Conductor XLPE Insulated PVC Sheathed Steel Tape Armored Three Cores Power Cable YJV22

6kV to 30kV Copper Conductor XLPE Insulated PVC Sheathed Steel Tape Armored Three Cores Power Cable YJV22


Construction:

Model: YJV22;

Voltage: 3.6/6KV, 6/6KV, 6/10KV, 8.7/10KV, 8.7/15KV, 12/20KV, 18/20KV, 18/30KV;

Conductor: Copper Conductor;

Insulation: XLPE;

Inner Sheath: PVC;

Armor: Steel Tape Armor;

Outer Sheath: PVC.


Overview

Operation Characteristics:

XLPE insulation: the long-term allowable working temperature of conductor shall not exceed 90℃, and the maximum temperature of conductor shall not exceed 250℃ in case of short circuit(the longest duration shall not exceed 5 seconds)

Reference Outer Diameter and Approximate Weight of 6kV to 30kV Copper Conductor XLPE Insulated PVC Sheathed Steel Tape Armored Three Cores Power Cable YJV22:

3.6/6 kV YJV22
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
3×2538.8 2436 
3×3541.1 2876 
3×5043.9 3394 
3×70  48.0 4208 
3×95  51.7 5150 
3×120  55.2 6120 
3×150  58.8 7161 
3×185  62.7 8405 
3x240  68.7 10394 
3×300  74.5 12565 
3×400  84.0 16559 
3×500  92.7 20442 



6/6kV and 6/10kV YJV22
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
3×2543.1 2788 
3×3545.2 3195 
3×5048.4 3770 
3×7052.5 4616 
3×9556.0 5579 
3×12059.5 6549 
3×15062.9 7572 
3×18567.08929
3×24072.3 10838 
3×30077.5 12958 
3×40085.8 16779 
3×50093.6 20560 



8.7/10kV and 8.7/15kV YJV22
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
3×2548.2 3204 
3×3550.6 3646 
3×5053.6 4228 
3×7057.3 5072 
3×9561.4 6120 
3×12064.8 7102 
3×15068.3 8214 
3×18572.1 9529 
3×24077.7 11491 
3×30084.0 14450 
3×40091.0 17641 
3×50099.0 21383 



12/20kV YJV22
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
3×25  52.9 3658 
3×35  55.2 4130 
3×50  58.2 4699 
3×70  62.0 5569 
3×95  65.9 6605 
3×120  69.2 7667 
3×150  72.6 8737 
3×185  76.8 10122 
3×240  83.6 12921 
3×300  88.4 15098 
3×400  95.7 18389 
3×500  103.5 22399 



18/20kV and 18/30kV YJV22
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
3×3567.8 5434 
3×5070.6 6181 
3×7074.5 7117 
3×9578.3 8232 
3×12083.2 10119 
3×15086.5 11330 
3×18590.6 12791 
3×24096.2 14916 
3×300101.0 17241 
3×400108.2 20606 
3×500116.1 24502 


Contact Us