6kV to 30kV Copper Conductor XLPE Insulated PVC Sheathed Non-magnetic Metal Wire Armored Single Core Power Cable YJV72
Construction:
Model: YJV72;
Voltage: 3.6/6KV, 6/6KV, 6/10KV, 8.7/10KV, 8.7/15KV, 12/20KV, 18/20KV, 18/30KV;
Conductor: Copper Conductor;
Insulation: XLPE;
Inner Sheath: PVC;
Armor: Non-magnetic Metal Wire Armor;
Outer Sheath: PVC.
Overview
Operation Characteristics:
XLPE insulation: the long-term allowable working temperature of conductor shall not exceed 90℃, and the maximum temperature of conductor shall not exceed 250℃ in case of short circuit(the longest duration shall not exceed 5 seconds)
Reference Outer Diameter and Approximate Weight of 6kV to 30kV Copper Conductor XLPE Insulated PVC Sheathed Non-magnetic Metal Wire Armored Single Core Power Cable YJV72:
3.6/6 kV YJV72 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×25 | 22.8 | 1137 |
1×35 | 23.8 | 268 |
1×50 | 25.1 | 1474 |
1×70 | 26.8 | 1753 |
1×95 | 28.6 | 2092 |
1×120 | 30.0 | 2411 |
1×150 | 31.7 | 2755 |
1×185 | 35.0 | 3428 |
1×240 | 37.5 | 4098 |
1×300 | 40.2 | 4838 |
1×400 | 43.9 | 5926 |
1×500 | 49.0 | 7618 |
1×630 | 53.2 | 9262 |
6/6kV and 6/10kV YJV72 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×25 | 24.7 | 1267 |
1×35 | 25.7 | 1418 |
1×50 | 26.9 | 1599 |
1×70 | 28.8 | 1896 |
1×95 | 30.4 | 2227 |
1×120 | 33.4 | 2781 |
1×150 | 35.1 | 3151 |
1×185 | 36.8 | 3605 |
1×240 | 39.3 | 4262 |
1×300 | 41.5 | 4983 |
1×400 | 45.8 | 6382 |
1×500 | 49.4 | 7648 |
1×630 | 53.6 | 9295 |
8.7/10kV and 8.7/15kV YJV72 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×25 | 26.9 | 1426 |
1×35 | 28.1 | 592 |
1×50 | 29.3 | 1778 |
1×70 | 31.2 | 2083 |
1×95 | 34.4 | 2661 |
1×120 | 35.8 | 2992 |
1×150 | 37.3 | 3351 |
1×185 | 39.2 | 3829 |
1×240 | 41.6 | 4495 |
1×300 | 43.7 | 5205 |
1×400 | 48.2 | 6681 |
1×500 | 52.0 | 7981 |
1×630 | 56.0 | 9622 |
12/20kV YJV72 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×25 | 29.0 | 1593 |
1×35 | 30.0 | 1750 |
1×50 | 31.4 | 1954 |
1×70 | 34.7 | 2476 |
1×95 | 36.3 | 2846 |
1×120 | 37.9 | 3198 |
1×150 | 39.4 | 3562 |
1×185 | 41.2 | 4046 |
1×240 | 43.5 | 4702 |
1×300 | 47.1 | 5865 |
1×400 | 50.3 | 6931 |
1×500 | 54.1 | 8244 |
1×630 | 58.2 | 9924 |
18/20kV and 18/30kV YJV72 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×35 | 37.1 | 2464 |
1×50 | 38.5 | 2700 |
1×70 | 40.2 | 3014 |
1×95 | 41.9 | 3417 |
1×120 | 43.3 | 3764 |
1×150 | 46.1 | 4552 |
1×185 | 48.0 | 5058 |
1×240 | 50.5 | 5761 |
1×300 | 52.8 | 6562 |
1×400 | 56.1 | 7723 |
1×500 | 59.7 | 9046 |
1×630 | 64.1 | 10794 |