6kV to 30kV Aluminium Conductor XLPE Insulated PVC Sheathed Steel Wire Armored Three Cores Power Cable YJLV32
Construction:
Model: YJLV32;
Voltage: 3.6/6KV, 6/6KV, 6/10KV, 8.7/10KV, 8.7/15KV, 12/20KV, 18/20KV, 18/30KV;
Conductor: Aluminium Conductor;
Insulation: XLPE;
Inner Sheath: PVC;
Armor: Steel Wire Armor;
Outer Sheath: PVC.
Overview
Operation Characteristics:
XLPE insulation: the long-term allowable working temperature of conductor shall not exceed 90℃, and the maximum temperature of conductor shall not exceed 250℃ in case of short circuit(the longest duration shall not exceed 5 seconds)
Reference Outer Diameter and Approximate Weight of 6kV to 30kV Aluminium Conductor XLPE Insulated PVC Sheathed Steel Wire Armored Three Cores Power Cable YJLV32:
3.6/6 kV YJLV32 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
3×25 | 40.9 | 2717 |
3×35 | 44.3 | 3385 |
3×50 | 47.1 | 3763 |
3×70 | 51.2 | 4346 |
3×95 | 54.9 | 4911 |
3×120 | 58.4 | 5497 |
3×150 | 62.0 | 6131 |
3×185 | 65.9 | 6718 |
3x240 | 71.8 | 7979 |
3×300 | 79.0 | 10005 |
3×400 | 87.2 | 11749 |
3×500 | 96.0 | 4033 |
6/6kV and 6/10kV YJLV32 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
3×25 | 46.3 | 3524 |
3×35 | 48.6 | 3866 |
3×50 | 51.6 | 4276 |
3×70 | 55.6 | 4891 |
3×95 | 59.2 | 5479 |
3×120 | 62.7 | 6063 |
3×150 | 66.1 | 6682 |
3×185 | 70.2 | 7375 |
3×240 | 76.8 | 9340 |
3×300 | 82.0 | 10547 |
3×400 | 89.0 | 11981 |
3×500 | 97.1 | 14172 |
8.7/10kV and 8.7/15kV YJLV32 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
3×25 | 51.4 | 4104 |
3×35 | 53.8 | 4458 |
3×50 | 56.7 | 4897 |
3×70 | 60.5 | 5474 |
3×95 | 64.6 | 6184 |
3×120 | 68.0 | 6782 |
3×150 | 72.7 | 8267 |
3×185 | 76.6 | 8992 |
3×240 | 82.2 | 10235 |
3×300 | 87.2 | 11484 |
3×400 | 94.3 | 13030 |
3×500 | 102.3 | 15139 |
12/20kV YJLV32 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
3×25 | 56.0 | 4692 |
3×35 | 58.4 | 5076 |
3×50 | 61.4 | 5502 |
3×70 | 65.2 | 6105 |
3×95 | 69.1 | 6802 |
3×120 | 73.8 | 8254 |
3×150 | 77.3 | 9014 |
3×185 | 81.3 | 9770 |
3×240 | 86.8 | 11061 |
3×300 | 91.7 | 12276 |
3×400 | 99.0 | 13917 |
3×500 | 106.8 | 16305 |
18/20kV and 18/30kV YJLV32 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
3×35 | 70.9 | 6759 |
3×50 | 75.1 | 8192 |
3×70 | 79.0 | 8890 |
3×95 | 83.0 | 9760 |
3×120 | 86.4 | 10466 |
3×150 | 89.8 | 11270 |
3×185 | 93.9 | 12085 |
3×240 | 99.5 | 13514 |
3×300 | 104.2 | 14816 |
3×400 | 111.5 | 16515 |
3×500 | 119.3 | 18868 |