6kV to 30kV Aluminium Conductor XLPE Insulated PVC Sheathed Steel Wire Armored Three Cores Power Cable YJLV32

6kV to 30kV Aluminium Conductor XLPE Insulated PVC Sheathed Steel Wire Armored Three Cores Power Cable YJLV32


Construction:

Model: YJLV32;

Voltage: 3.6/6KV, 6/6KV, 6/10KV, 8.7/10KV, 8.7/15KV, 12/20KV, 18/20KV, 18/30KV;

Conductor: Aluminium Conductor;

Insulation: XLPE;

Inner Sheath: PVC;

Armor: Steel Wire Armor;

Outer Sheath: PVC.


Overview

Operation Characteristics:

XLPE insulation: the long-term allowable working temperature of conductor shall not exceed 90℃, and the maximum temperature of conductor shall not exceed 250℃ in case of short circuit(the longest duration shall not exceed 5 seconds)

Reference Outer Diameter and Approximate Weight of 6kV to 30kV Aluminium Conductor XLPE Insulated PVC Sheathed Steel Wire Armored Three Cores Power Cable YJLV32:

3.6/6 kV YJLV32
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
3×2540.9 2717 
3×3544.3 3385 
3×5047.1 3763 
3×70  51.2 4346 
3×95  54.9 4911 
3×120  58.4 5497 
3×150  62.0 6131 
3×185  65.9 6718 
3x240  71.8 7979 
3×300  79.0 10005 
3×400  87.2 11749 
3×500  96.0 4033 



6/6kV and 6/10kV YJLV32
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
3×2546.3 3524 
3×3548.6 3866 
3×5051.6 4276 
3×7055.6 4891 
3×9559.2 5479 
3×12062.7 6063 
3×15066.1 6682 
3×18570.27375
3×24076.8 9340 
3×30082.0 10547 
3×40089.0 11981 
3×50097.1 14172 



8.7/10kV and 8.7/15kV YJLV32
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
3×2551.4 4104 
3×3553.8 4458 
3×5056.7 4897 
3×7060.5 5474 
3×9564.6 6184 
3×12068.0 6782 
3×15072.7 8267 
3×18576.6 8992 
3×24082.2 10235 
3×30087.2 11484 
3×40094.3 13030 
3×500102.3 15139 



12/20kV YJLV32
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
3×2556.0 4692 
3×3558.4 5076 
3×5061.4 5502 
3×7065.2 6105 
3×9569.1 6802 
3×12073.8 8254 
3×15077.3 9014 
3×18581.3 9770 
3×24086.8 11061 
3×30091.7 12276 
3×40099.0 13917 
3×500106.8 16305 



18/20kV and 18/30kV YJLV32
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
3×3570.9 6759 
3×5075.1 8192 
3×7079.0 8890 
3×9583.0 9760 
3×12086.4 10466 
3×15089.8 11270 
3×18593.9 12085 
3×24099.5 13514 
3×300104.2 14816 
3×400111.5 16515 
3×500119.3 18868 


Contact Us