6kV to 30kV Aluminium Conductor XLPE Insulated PVC Sheathed Non-magnetic Metal Wire Armored Single Core Power Cable YJLV72

6kV to 30kV Aluminium Conductor XLPE Insulated PVC Sheathed Non-magnetic Metal Wire Armored Single Core Power Cable YJLV72


Construction:

Model: YJLV72;

Voltage: 3.6/6KV, 6/6KV, 6/10KV, 8.7/10KV, 8.7/15KV, 12/20KV, 18/20KV, 18/30KV;

Conductor: Aluminium Conductor;

Insulation: XLPE;

Inner Sheath: PVC;

Armor: Non-magnetic Metal Wire Armore;

Outer Sheath: PVC.


Overview

Operation Characteristics:

XLPE insulation: the long-term allowable working temperature of conductor shall not exceed 90℃, and the maximum temperature of conductor shall not exceed 250℃ in case of short circuit(the longest duration shall not exceed 5 seconds)


Reference Outer Diameter and Approximate Weight of 6kV to 30kV Aluminium Conductor XLPE Insulated PVC Sheathed Non-magnetic Metal Wire Armored Single Core Power Cable YJLV72:

3.6/6 kV YJLV72
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
1×2522.8 983 
1×3523.8 1056 
1×5025.1 1189 
1×7026.8 1345 
1×9528.6 1524 
1×12030.0 1678 
1×15031.7 1851 
1×18535.0 2260 
1×24037.5 2636 
1×30040.2 2991 
1×40043.9 3488 
1×50049.0 4531 
1×63053.2 5264 



6/6kV and 6/10kV YJLV72
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
1×25  24.7 1107 
1×35  25.7 1202 
1×50  26.9 1329 
1×70  28.8 1499 
1×95  30.4 1671 
1×120  33.4 2019 
1×150  35.1 2215 
1×185  36.8 2407 
1×240  39.3 2763 
1×300  41.5 3098 
1×400  45.8 3903 
1×500  49.4 4566 
1×630  53.6 5342 



8.7/10kV and 8.7/15kV YJLV72
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
1×2526.9 1272 
1×3528.1 1380 
1×5029.3 1493 
1×7031.2 1674 
1×9534.4 2093 
1×12035.8 2259 
1×15037.3 2447 
1×18539.2 2659 
1×24041.6 3033 
1×30043.7 3359 
1×40048.2 4201 
1×50052.0 4894 
1×63056.0 5624 



12/20kV YJLV72
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
1×25   29.0 1439 
1×35   30.0 1538 
1×50   31.4 1669 
1×70   34.7 2068 
1×95   36.3 2278 
1×120   37.9 2465 
1×150   39.4 2658 
1×185   41.2 2876 
1×240   43.5 3240 
1×300   47.1 4019 
1×400   50.3 4489 
1×500   54.1 5157 
1×630   58.2 5963 



18/20kV and 18/30kV YJLV72
Number of cores × nominal cross-sectional area
(mm²)
Reference outer diameter
(mm)
Reference weight
(kg/km)
1×3537.1 2252 
1×5038.5 2415 
1×7040.2 2606 
1×9541.9 2849 
1×12043.3 3031 
1×150  46.1 3648 
1×185  48.0 3870 
1×240  50.5 4299 
1×300  52.8 4716 
1×400  56.1 5236 
1×500  59.7 5959 
1×630  64.1 6830 