6kV to 30kV Aluminium Conductor XLPE Insulated PVC Sheathed Non-magnetic Metal Wire Armored Single Core Power Cable YJLV72
Construction:
Model: YJLV72;
Voltage: 3.6/6KV, 6/6KV, 6/10KV, 8.7/10KV, 8.7/15KV, 12/20KV, 18/20KV, 18/30KV;
Conductor: Aluminium Conductor;
Insulation: XLPE;
Inner Sheath: PVC;
Armor: Non-magnetic Metal Wire Armore;
Outer Sheath: PVC.
Overview
Operation Characteristics:
XLPE insulation: the long-term allowable working temperature of conductor shall not exceed 90℃, and the maximum temperature of conductor shall not exceed 250℃ in case of short circuit(the longest duration shall not exceed 5 seconds)
Reference Outer Diameter and Approximate Weight of 6kV to 30kV Aluminium Conductor XLPE Insulated PVC Sheathed Non-magnetic Metal Wire Armored Single Core Power Cable YJLV72:
3.6/6 kV YJLV72 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×25 | 22.8 | 983 |
1×35 | 23.8 | 1056 |
1×50 | 25.1 | 1189 |
1×70 | 26.8 | 1345 |
1×95 | 28.6 | 1524 |
1×120 | 30.0 | 1678 |
1×150 | 31.7 | 1851 |
1×185 | 35.0 | 2260 |
1×240 | 37.5 | 2636 |
1×300 | 40.2 | 2991 |
1×400 | 43.9 | 3488 |
1×500 | 49.0 | 4531 |
1×630 | 53.2 | 5264 |
6/6kV and 6/10kV YJLV72 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×25 | 24.7 | 1107 |
1×35 | 25.7 | 1202 |
1×50 | 26.9 | 1329 |
1×70 | 28.8 | 1499 |
1×95 | 30.4 | 1671 |
1×120 | 33.4 | 2019 |
1×150 | 35.1 | 2215 |
1×185 | 36.8 | 2407 |
1×240 | 39.3 | 2763 |
1×300 | 41.5 | 3098 |
1×400 | 45.8 | 3903 |
1×500 | 49.4 | 4566 |
1×630 | 53.6 | 5342 |
8.7/10kV and 8.7/15kV YJLV72 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×25 | 26.9 | 1272 |
1×35 | 28.1 | 1380 |
1×50 | 29.3 | 1493 |
1×70 | 31.2 | 1674 |
1×95 | 34.4 | 2093 |
1×120 | 35.8 | 2259 |
1×150 | 37.3 | 2447 |
1×185 | 39.2 | 2659 |
1×240 | 41.6 | 3033 |
1×300 | 43.7 | 3359 |
1×400 | 48.2 | 4201 |
1×500 | 52.0 | 4894 |
1×630 | 56.0 | 5624 |
12/20kV YJLV72 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×25 | 29.0 | 1439 |
1×35 | 30.0 | 1538 |
1×50 | 31.4 | 1669 |
1×70 | 34.7 | 2068 |
1×95 | 36.3 | 2278 |
1×120 | 37.9 | 2465 |
1×150 | 39.4 | 2658 |
1×185 | 41.2 | 2876 |
1×240 | 43.5 | 3240 |
1×300 | 47.1 | 4019 |
1×400 | 50.3 | 4489 |
1×500 | 54.1 | 5157 |
1×630 | 58.2 | 5963 |
18/20kV and 18/30kV YJLV72 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×35 | 37.1 | 2252 |
1×50 | 38.5 | 2415 |
1×70 | 40.2 | 2606 |
1×95 | 41.9 | 2849 |
1×120 | 43.3 | 3031 |
1×150 | 46.1 | 3648 |
1×185 | 48.0 | 3870 |
1×240 | 50.5 | 4299 |
1×300 | 52.8 | 4716 |
1×400 | 56.1 | 5236 |
1×500 | 59.7 | 5959 |
1×630 | 64.1 | 6830 |