6kV to 30kV Aluminium Conductor XLPE Insulated PVC Sheathed Non-magnetic Metal Tape Armored Single Core Power Cable YJLV62
Construction:
Model: YJLV62;
Voltage: 3.6/6KV, 6/6KV, 6/10KV, 8.7/10KV, 8.7/15KV, 12/20KV, 18/20KV, 18/30KV;
Conductor: Aluminium Conductor;
Insulation: XLPE;
Inner Sheath: PVC;
Armor: Non-magnetic Metal Tape Armor;
Outer Sheath: PVC.
Overview
Operation Characteristics:
XLPE insulation: the long-term allowable working temperature of conductor shall not exceed 90℃, and the maximum temperature of conductor shall not exceed 250℃ in case of short circuit(the longest duration shall not exceed 5 seconds)
Reference Outer Diameter and Approximate Weight of 6kV to 30kV Aluminium Conductor XLPE Insulated PVC Sheathed Non-magnetic Metal Tape Armored Single Core Power Cable YJLV62:
3.6/6 kV YJLV62 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×25 | 19.6 | 564 |
1×35 | 20.6 | 627 |
1×50 | 22.0 | 717 |
1×70 | 23.7 | 834 |
1×95 | 25.4 | 972 |
1×120 | 26.8 | 085 |
1×150 | 28.5 | 1234 |
1×185 | 30.2 | 1376 |
1×240 | 32.9 | 1654 |
1×300 | 37.0 | 2300 |
1×400 | 40.5 | 2696 |
1×500 | 44.6 | 3261 |
1×630 | 48.8 | 3892 |
6/6kV and 6/10kV YJLV62 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×25 | 21.6 | 651 |
1×35 | 22.6 | 720 |
1×50 | 23.9 | 816 |
1×70 | 25.6 | 932 |
1×95 | 27.4 | 1076 |
1×120 | 28.8 | 1194 |
1×150 | 30.5 | 1345 |
1×185 | 32.2 | 1494 |
1×240 | 35.9 | 2081 |
1×300 | 38.2 | 2369 |
1×400 | 41.4 | 2777 |
1×500 | 45.0 | 3305 |
1×630 | 49.2 | 3938 |
8.7/10kV and 8.7/15kV YJLV62 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×25 | 23.8 | 761 |
1×35 | 24.9 | 842 |
1×50 | 26.1 | 929 |
1×70 | 28.0 | 1070 |
1×95 | 29.6 | 1207 |
1×120 | 31.2 | 1344 |
1×150 | 32.7 | 1489 |
1×185 | 35.8 | 1982 |
1×240 | 38.3 | 2293 |
1×300 | 40.5 | 2594 |
1×400 | 43.8 | 2991 |
1×500 | 47.6 | 3547 |
1×630 | 51.6 | 4170 |
12/20kV YJLV62 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×25 | 25.8 | 873 |
1×35 | 27.0 | 958 |
1×50 | 28.2 | 1049 |
1×70 | 30.1 | 1197 |
1×95 | 31.7 | 1339 |
1×120 | 33.3 | 1481 |
1×150 | 36.0 | 1964 |
1×185 | 37.9 | 2150 |
1×240 | 40.3 | 2472 |
1×300 | 42.7 | 2799 |
1×400 | 45.9 | 3187 |
1×500 | 49.7 | 3758 |
1×630 | 53.9 | 4421 |
18/20kV and 18/30kV YJLV62 | ||
Number of cores × nominal cross-sectional area (mm²) | Reference outer diameter (mm) | Reference weight (kg/km) |
1×35 | 32.5 | 1292 |
1×50 | 33.9 | 1409 |
1×70 | 37.0 | 1915 |
1×95 | 38.6 | 20488 |
1×120 | 40.1 | 2260 |
1×150 | 41.7 | 2458 |
1×185 | 43.6 | 2660 |
1×240 | 46.1 | 3008 |
1×300 | 48.4 | 3342 |
1×400 | 51.6 | 3754 |
1×500 | 55.4 | 4366 |
1×630 | 59.7 | 5092 |